Installationandwiring

Type 8025 /8035 Batch

Respect▶the▶following▶additional▶mounting▶conditions▶to▶ensure▶
that▶the▶measuring▶device▶operates▶correctly:▶

- Ensure▶that▶the▶pipe▶is▶always▶filled▶in▶the▶section▶around▶the▶

device▶(see▶„Fig.▶8“).

- When▶mounting▶vertically▶ensure▶that▶the▶flow▶direction▶is▶in▶an▶

upward▶direction▶(see▶„Fig.▶8“).

Horizontal▶mounting

Correct

Incorrect

Vertical▶mounting

Correct

Incorrect

flow▶direction

Fig. 8: Filling of the pipe

If▶necessary,▶use▶a▶flow▶conditioner▶to▶improve▶measurement▶
precision.

7.2.2 installation onto the pipe

1

2

3

5

4

6

Install▶the▶S020▶fitting▶into▶the▶pipe▶taking▶
into▶account▶the▶recommendations▶in▶chap.▶
„7.2.1“

.

Check▶that▶there▶is▶a▶seal▶on▶the▶fitting▶and▶
that▶ it▶ is▶ not▶ damaged.▶ Replace▶ the▶ seal▶ if▶
necessary.

Check▶ that▶ there▶ is▶ a▶ seal▶ (mark▶ 6)▶ on▶ the▶
flow▶sensor.

Insert▶the▶nut▶(mark▶3)▶on▶the▶fitting.

Insert▶the▶snap▶ring▶(mark▶2)▶into▶the▶groove▶
(mark▶5).

Position▶the▶device▶in▶order▶the▶arrow▶on▶the▶
side▶of▶the▶housing▶indicates▶the▶direction▶of▶
the▶flow.▶The▶totalizers▶will▶increment.

Insert▶the▶device▶(mark▶1)▶into▶the▶fitting.

Tighten▶the▶nut▶(mark▶3)▶by▶hand▶on▶the▶
device.