Installationandwiring

Type 8025 /8035 Batch

Type▶of▶signal▶
emitted▶by▶the▶
remote▶flow▶
sensor

Selector▶

"SENSOR▶TYPE"▶

(

C

)

Selector▶"SENSOR▶

SUPPLY"▶

(

A

)▶

Selector▶"LOAD"

B

LOAD

COIL/PNP

39K

470

2.2K

Terminal▶assignment▶of▶terminal▶block▶

"FLOW▶SENSOR"

FLOW

SENSOR

SUPPLY

NC

COIL

PULSE INPUT

NPN/PNP

2

1

3

PE

+

-

0-5▶V▶DC▶
standard▶voltage▶
signal▶(TTL,▶for▶
example)

Set▶the▶
selector▶on▶
"NPN/PNP"▶
(„Fig.▶28“)

Set▶the▶selector▶as▶
shown▶in▶„Fig.▶29“.

Set▶selector▶"LOAD"▶on▶"39K":▶
the▶input▶impedance▶on▶ter-
minals▶1▶and▶2▶of▶terminal▶block▶
"FLOW▶SENSOR"▶will▶then▶be▶
39▶kW

2

1

3 PE

39 kΩ

8025

Flow▶sensor

English