Burkert Type 8035 User Manual

Page 31

Advertising
background image

29

Installationandwiring

Type 8025 /8035 Batch

7.6.4 Wiring a compact version

Only▶move▶the▶selectors▶when▶the▶power▶supply▶is▶off.

Insert▶the▶supplied▶stopper▶gasket▶into▶the▶unused▶cable▶
gland▶to▶ensure▶the▶tightness▶of▶the▶device.

•▶ Unscrew▶the▶unused▶cable▶gland.
•▶ Remove▶the▶transparent▶disk.
•▶ Insert▶the▶supplied▶stopper▶gasket.
•▶ Screw▶the▶nut▶of▶the▶cable▶gland.

Set▶the▶selector▶"SENSOR▶TYPE"▶on▶"NPN/PNP".▶See▶„Fig.▶21“.

Never▶set▶selector▶"SENSOR▶TYPE"▶on▶the▶left▶on▶a▶
compact▶version.

Selector▶

C

▶makes▶it▶possible▶to▶configure▶the▶type▶of▶signal▶

received▶from▶the▶flow▶sensor.

C

SENSOR TYPE

COIL

NPN/PNP

SENSOR TYPE

COIL

NPN/PNP

On▶a▶compact▶version,▶set▶the▶selector▶on▶the▶right▶(default▶
position).

Fig. 21: Using selector "SENSOR TYPE" on a compact version

Set▶selector▶"SENSOR▶SUPPLY"▶depending▶on▶the▶value▶of▶the▶
power▶supply▶of▶the▶dosing▶controller.▶See▶„Tab.▶4“.

Set▶selector▶"LOAD":▶See▶„Tab.▶4“.

Tab. 4: Position of selectors "SENSOR TYPE", "SENSOR

SUPPLY" and "LOAD" on a compact version

Selector▶"SENSOR▶

TYPE"▶(

C

)

Set▶the▶selector▶on▶"NPN/PNP"▶(„Fig.▶
21“)

Selector▶"SENSOR▶

SUPPLY"

SENSOR

SUPPL

Y

+5V

L+

(L+)-12V

A

The▶flow▶sensor▶of▶the▶compact▶version▶
needs▶a▶minimum▶voltage▶supply▶of▶
5▶V▶DC▶:

If▶the▶device▶is▶fed▶with▶a▶voltage ≥▶
12▶V▶DC ▶and▶<▶17▶V▶DC,▶set▶the▶
voltage▶selector▶"SENSOR▶SUPPLY"▶
on▶"5V"▶or▶"L+".

If▶the▶device▶is▶fed▶with▶a▶voltage

≥▶17▶V▶DC,▶the▶voltage▶selector▶
"SENSOR▶SUPPLY"▶can▶be▶set▶to▶
any▶position.

If▶the▶device▶is▶fed▶with▶a▶▶
115/230V▶AC▶voltage,▶set▶the▶voltage▶
selector▶"SENSOR▶SUPPLY"▶on▶"L+".

English

Advertising
This manual is related to the following products: