50

Adjustmentandcommissioning

Type 8025 /8035 Batch

Displayed▶in▶the▶Process▶level▶when▶the▶configured▶dosing▶mode▶is▶"LOC.▶REP".▶
Do▶a▶dosing,▶using▶the▶navigation▶keys,▶of▶the▶quantity▶determined▶by▶means▶of▶a▶Teach-In▶procedure.
Displayed▶in▶the▶Process▶level▶when▶the▶configured▶dosing▶mode▶is▶"EXT.+LOC".▶
Do:
•▶ a▶dosing▶using▶the▶digital▶inputs.
•▶ or▶a▶semi-automatic▶dosing:▶the▶quantity▶to▶be▶dosed▶is▶chosen▶via▶the▶navigation▶keys▶but▶the▶dosing▶is▶started▶

using▶the▶digital▶inputs.

Value▶of▶the▶main▶volume▶or▶mass▶totalizer,▶total▶quantity▶of▶fluid▶counted▶by▶the▶device▶since▶the▶last▶reset.

Value▶of▶the▶daily▶volume▶or▶mass▶totalizer▶(identified▶by▶a▶dot▶after▶the▶volume▶or▶mass▶units),▶quantity▶of▶fluid▶
counted▶by▶the▶device▶since▶the▶last▶reset.

BAtCH R.

BAtCH S.

87654 L

231 L.

0......9

0......9

>▶2▶s

Resets:
•▶ the▶daily▶volume▶or▶mass▶totalizer▶(identified▶by▶a▶dot▶after▶the▶volume▶or▶mass▶units).
•▶ or▶the▶daily▶totalizer▶of▶the▶carried▶out▶dosings▶(identified▶by▶a▶dot▶after▶letter▶B).

+

1254 B

21 B.

Value▶of▶the▶daily▶totalizer▶of▶the▶carried▶out▶dosings▶(identified▶by▶a▶dot▶after▶letter▶B)▶since▶the▶last▶reset.

Value▶of▶the▶main▶totalizer▶of▶the▶carried▶out▶dosings▶since▶the▶last▶reset.

Displayed▶in▶the▶Process▶level▶when▶the▶configured▶dosing▶mode▶is▶"LOC▶MANU"▶(default▶mode,▶see▶chap.▶
„8.5.1“)▶or▶"MEM+MANU".▶
Do▶a▶dosing▶by▶entering▶the▶quantity▶to▶be▶dosed▶using▶the▶navigation▶keys.

Displayed▶in▶the▶Process▶level▶when▶the▶configured▶dosing▶mode▶is▶"LOC▶MEM"▶or▶"MEM+MANU".▶
Do▶a▶dosing▶by▶choosing▶the▶quantity▶to▶be▶dosed▶in▶the▶device▶memory▶using▶the▶navigation▶keys.