HOMA GRP TP Motor Voltage Change User Manual

Grp, tp motor voltage change

Advertising
background image

Publication

88FN2045A

Please Contact Technical Support At 203-736-8890 With Any Additional Questions

Please Be Prepared To Provide Pump Serial Number During Call

Page

1 of 5

GRP, TP Motor Voltage Change

This procedure will provide you with step by step instructions to

convert 208/230 V operating voltage to 460V in dual voltage motors.




1. Remove pump from service. Disconnect

power supply. Clean and decontaminate
pump prior to working on it. See the
pump Installation, Operation, and
Maintenance Manual for detailed
instructions.


2. With pump in stable, upright position,

remove the 5mm cap screws as
indicated.














3. Carefully lift stator housing 3 inches with

hoist, if available, and check under stator
housing for internal seal probe.
CAREFUL: lifting housing more than 3
inches may damage seal probe. If no
hoist is available, lift by hand and slide
the 2x4s under the housing to hold it up.
Disconnect probe if installed. Carefully lift
stator housing off the pump.

You Need:

5mm Allen Wrench
Wire Cutters
Wire Strippers
Terminal Crimp Tool
Qty 6-Crimpable Wire Nut
Hoist or Qty 2-2x4s

Advertising