HOMA GRP TP Motor Voltage Change User Manual

Page 3

Advertising
background image

Publication

88FN2045A

Please Contact Technical Support At 203-736-8890 With Any Additional Questions

Please Be Prepared To Provide Pump Serial Number During Call

Page

3 of 5


7. Separate the wire bundles as indicated,

and record the wire numbers in each
bundle.


The pump will have 4 wire bundles.

Bundle 1 ___

___

___


Bundle 2 ___

___

___


Bundle 3 ___

___

___


Bundle 4 ___

___

___



Note: The wire numbers for 6 and 9 appear
as 6 and 9.


8. To convert from 230V to 460V operation,

you will need to separate the wire
bundles, one at a time, and reconnect as
indicated below.


Note: Refer to markers on the end of the
cable to identify L1, L2, and L3. If markers
are missing, consult HOMA document
number 88WA3005A-“How to Determine
Cable ID Wire Numbers” available online.


9. To perform the reconnection, locate the

wire bundle with wires 1, 7, and the
power lead. Cut wire connector from the
bundle, freeing individual wires. Strip
wire sheathing back ¼ in preparation for
reconnection.