4. Sometimes the housing will be difficult to

remove. Twist the housing ¼ turn (90
degrees), exposing the bottom of the
cable entry horn. Using a soft faced
hammer, gently tap the cable entry horn
to free the stator housing.



5. With stator housing removed, determine if

a wavy washer is present by checking the
top of the bearing, the top of the stator
housing, and the stator windings. Place it
aside until reassembly.










6. With motor disassembled, turn stator

housing upside down, and support it so it
is free standing. Stator windings and
cable leads must be visible and easy to
reach. Your unit should now look like
this. Gently remove all wires from around
the stator windings. Take care not to
damage the winding insulation. Do not
use sharp tools!!