15. Starting with bundles 4-7, 5-8, 6-9, gently

tuck these 3 wire bundles behind the
windings on one side of stator. Then tuck
the remaining 3 bundles behind the
windings on the other side. Take care that
all wires are tucked between stator
winding and housing. Also check that
white phase paper is in proper position,
and not extending below the stator
housing.



The pump is now ready for reassembly


16. Place the wavy washer on top of upper

bearing if present. Use a little bit of
grease to hold in position if necessary.
Verify that the large o ring is still in its
proper position on the pump housing.

17. Reinstall the internal seal probe if

necessary while gently placing motor
housing back onto pump. Take care not
to disturb washer when reinstalling.

18. With motor housing back in position,

rotate motor housing until cable entry
horn is in line with pump discharge as
indicated in photo. Then align bolt holes
and replace capscrews. Tighten
capscrews to 12 ft/lbs.

19. Pump should now be ready for installation

and operation at 460V. Be sure to record
that voltage has been changed in pump
service manual.