HOMA GRP TP Motor Voltage Change User Manual

Page 4

Advertising
background image

Publication

88FN2045A

Please Contact Technical Support At 203-736-8890 With Any Additional Questions

Please Be Prepared To Provide Pump Serial Number During Call

Page

4 of 5

10. Select wire number 1 and the power lead.

Reconnect these 2 wires with the
crimpable wire nut (close end connector).
Leave wire number 7 loose for now.



11. Repeat procedure for wire bundle 2, 8,

and power. After separating wires,
reconnect wire number 2 and power lead
with crimpable wire nut. Leave wire
number 8 loose for now.


12. Repeat procedure for wire bundle 3, 9,

and power. After separating wires
reconnect wire number 3 and power lead
with crimpable wire nut. Leave wire
number 9 loose for now.



Now you should have three new bundles
2 and power
3 and power
1 and power
along with 3 separate wires (#7,#8,#9), and
one bundle of 3 wires (#4,#5,#6).


13. Now, you will need to separate the wire

bundle with numbers 4, 5, 6, and pair
each wire with the loose wires numbers 7,
8, and 9 as indicated. Using the last
three wire connectors:

Join wire #4 to wire #7
Join wire #5 to wire #8
Join wire #6 to wire #9


14. At this point, you should have 6 separate

wire bundles, each with 2 wires. Wires
should be paired as follows: 4 to 7, 5 to 8,
6 to 9, #1 to power, #2 to power and #3 to
power.



Before proceeding, you should check the
resistance between all three cable leads
is the same. Resistance value is different
for the various size motors, so please
consult wiring handbook for specific
resistance values, if required.