Approach Tech DVR-3024 User Manual

Page 34

Advertising
background image

32

D uration
Setting

Alarm

activated

Alarm

deactivated

R eset

Alarm recording

N on-Stop

Alarm

activated

Alarm

deactivated

D uration

Alarm recording

D uration

REC RATE:

This option is for the purpose of adjusting the

number of pictures recorded every second

into a storage disk when an alarm input is

activated. For an NTSC unit, there are 5

different record speeds you can select from:

30F/S (30 fields per second), 15F/S, 10F/S,

6F/S, and REMAIN. For a PAL unit, there are

5 different record speeds you can select from:

25F/S (25 fields per second), 12.5F/S,

8.3F/S, 5F/S, and REMAIN. If you select

REMAIN for use, the device will record

images at the same speed as set on the REC

page.

REC QUALITY:

This option determines the image quality to

be recorded when an alarm input occurs.

There are 4 levels of image quality to choose

from: BEST, HIGH, STANDARD, and BASIC.

The table below shows the level of image

quality with the corresponding compression

ratio and image size.

REC
Quality

Best High Standard

Basic

Image
Size

60KB 50KB 40KB 32KB

AUDIO:

This option determines the way to record

sound if necessary.

OFF: Disables AUDIO recording.

11KHZ: Enables AUDIO recording and

records at the 11KHz sampling rate.

22KHZ: Enables AUDIO recording and

records at the 22KHz sampling rate.

NOTE: Audio function can only be activated in

the following refresh rate in NTSC(PAL):

30(25), 15(12.5), 10(8.3), 6(5), 2.7(2.7)

fields/sec.

ALM TYPE:

This option allows users to set a type of alarm

input corresponding to the sensor signal in

use.

NO: Normally Open. This is to be used with

the type of alarm sensor whose contact

remains open in normal conditions and

closes in case of activation.

NC: Normally Closed. This is to be used with

the type of alarm sensor whose contact

remains closed in normal conditions and

opens in case of activation.

ALM DURATION:

This option allows users to set alarms for a

certain duration. You can select one of the six

following options: 0 SEC, 30SEC, 1 MIN, 5

MIN, 10 MIN, and NON-STOP.

NOTE: Recording may be interrupted during

Alarm-in or Alarm-out.

PRE- ALARM:

This option determines that images prior to an

alarm occurs will be recorded in the hard-disk

drive. When an alarm is triggered the device

will record the image prior to the alarm for 5

seconds (

10 frame / sec

).

ON: Enables this function.

OFF: Disables this function.

NOTE: If the device is already under recording

mode before an alarm occurs, the

pre-alarm recording will not take effect.

Advertising