Installation, Unpacking the rcs-2700, Wiring overview – Clear-Com RCS-2700 User Manual

Page 21: Installation -1, Unpacking the rcs-2700 -1 wiring overview -1

Advertising
background image

R C S - 2 7 0 0 S O U R C E A S S I G N M E N T P A N E L

2 - 1

INSTALLATION

UNPACKING THE RCS-2700

When you unpack the RCS-2700 Source Assignment Panel, you will find the
following items:

• RCS-2700 unit

• RCS-2700 manual

• 31 6-terminal Euro-block connectors

The Euro-block connectors press on to the rear-panel pins of the RCS-2700 unit.
They are used to wire the unit to destinations and sources. You can install the
connectors with the visible screws facing either upward or downward. However,
facing the screws upward, so that they are visible from above, allows more
flexibility in tightening the connections.

WIRING OVERVIEW

Four sets of pins on the rear panel of the RCS-2700 connect the unit to source
channels, destinations, expansion RCS-2700 units, and power.

An overview of the wiring is given below, with more detailed explanations and
diagrams following later in the chapter.

Figure 2-1: Four Sets of Connection Pins on the Rear Panel of an RCS-2700 Unit

13

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

DESTINATION POWER

1 2 3 4 5 6 7 8

SOURCE POWER

SCE

RCS PWR

13

DESTINATIONS

14

15

16

17

18

19

20

21

22

23

24

1

DESTINATIONS

2

3

4

5

6

7

8

9

10

11

12

1

SOURCES

2

3

4

5

6

7

8

SOURCE EXPANSIONS

14

15

16

17

18

19

20

21

22

23

24

1

SOURCE EXPANSIONS

2

3

4

5

6

7

8

9

10

11

12

MTX

CONT

DATA

LINKS

PC SERIAL

PORT

RCU-67

M

4

2

A

1

3

5

B

ADDRESS

1 2 3

8

4 5 6 7

TERMINATION

SWITCHES

ON
OFF

CODE RESET

1

2

3

4

Power Patch Panel

Source Connections (Power and Audio)

Destination Connections (Power and Audio)

Source-8 Connection Points
Tie Together or Connect to Expansion Units

• You connect the

RCS-2700 unit to source

channels, destinations,

expansion RCS-2700

units, and power.

2

Advertising