Powering from tw party-line sources, Powering from tw party-line sources -5 – Clear-Com RCS-2700 User Manual

Page 25

Advertising
background image

R C S - 2 7 0 0 S O U R C E A S S I G N M E N T P A N E L

2 - 5

POWERING FROM TW PARTY-LINE SOURCES

You can operate the RCS-2700 using TW party-line sources provided that each
source channel is powered. If power does not exist on every intercom channel,
you can add it using TWC-701 or TWC-704 TW Adapters. The wiring is as
shown in Figure 2-5. Because 2-amp relays are used, they can easily handle the
DC current on the line as they switch.

Figure 2-5: TW Source Wiring for a 4-Source System

When powering the stations this way, you should not connect the destination
power block to the source power block. Instead, connect a jumper wire on each
destination output using the connection options shown in Figure 2-5.

You can take RCS-2700 power from one of the source channels using the power
patch panel. The current drain of the RCS-2700 is designed not to interfere with
the audio on the powered source. You connect a jumper from the desired source

Source 4

Source 3

Source 2

Source 1

Main Unit

MS-704

4-Channel

Main Station

TWC-701

TWC-701

TWC-701

TWC-701

D C B A

A

A

A

A

TW

TW

TW

TW

1 2

Shield

3 (NC)

Turn MS-704

Channel

Terminations ON

Turn RCS-2700

Channel Terminations

1-4 OFF

1 2 3

Shield

TW Destination

Channels

1 & 2

3 & 4

5 & 6

7 & 8

9 & 10

11 & 12

Advertising