4 connecting user panels and interface modules, Connecting user panels and interface modules – Clear-Com HX System Frames User Manual

Page 25

Advertising
background image

Key to Figure 4 Rear panel connectors

Feature

Description

1


Two IEC AC power input connectors
(1 for each power-supply unit).

2


RJ-45 connectors (36).
For connecting the Eclipse HX-PiCo to remote user
panels (V-Series and i-Series user panels), interface modules, interface frames
and other intercom devices.

Note:

The last four ports are four-wire only.

3


General Purpose Outputs (GPOs) connector
. Male, 25-pin, D-Type

4


General Purpose Inputs (GPIs) connector
. Female, 25-pin, D-Type

5


GPI-6/RLY-6 interface module connector (RJ-45)
. Connector specifically
designed to connect GPI-6 and RLY-6 interface modules.

6


PiCo-Link connector (RJ-45)
. High capacity link for connecting two Eclipse HX-
PiCo matrices together, forming a non-blocking system of 72 ports.

7


LAN connector (RJ-45).
For Ethernet connections.

Table 4: Key to Figure 4: Rear panel connectors

4.4 Connecting user panels and interface modules

An Eclipse HX-PiCo rear panel contains 36 RJ-45 sockets for connecting the matrix to remote
user panels (V-Series and I-Series user panels), interface modules and other intercom devices.
These sockets are often called ports. Each port socket is given a number on the rear-panel for
easy identification.

All ports contain a voice detection mechanism (VOX) that is programmed in EHX software. VOX
detection:

• Allows the panel operator to know when the audio on a particular channel has

exceeded a threshold.

• Is particularly useful for channels that are inactive periodically, so that the panel

operator is visually cued in the software when audio appears on the line.

25

Eclipse HX-PiCo User Guide

Advertising
This manual is related to the following products: