CellCom/FreeSpeak Firmware Update Procedures

Rev: 6.05

VGC Part No.- 810372Z-MAN-6

Page 5 of 49

2 Beltpack Firmware Upgrade

2.1 Software and Hardware Required.

1. FreeSpeak Upgrader – supplied on CD

2. FreeSpeak Registation Serial Cable

3. Latest release of Bootloader and Beltpack – supplied on CD

4. PC with a serial connection

2.2 Beltpack Upgrades

To upgrade beltpack firmware, install the Beltpack Upgrader tool in the "PC Tools"
directory of this CDROM. This program will be installed as "Freespeak Upgrader",
and by default will be installed in the "Drake Electronics" program group. More help
on the upgrade procedure is available from within this program.

The MKII can be quickly identified by the letter „A‟ at the end of the unit‟s serial
number or by the software version starting with the letters“3K”. Alternatively you can
enter programming mode on the beltpack and goto the software version menu.

Beltpack firmware can be found in the "Firmware\Beltpack" directory of the CD.

To upgrade the Beltpack, follow the flow chart on the next page.