The basics, Cautions and warnings, Identifying the electrical wires in your home – INSTEON SwitchLinc Dimmer (Dual-Band) - (2477D) Manual (Version 7.0 and Newer) User Manual

Page 3: Installation, The basics cautions and warnings

Advertising
background image

Page 3 of 16 Rev: 3/29/2013 10:32 AM

The Basics

Cautions and Warnings

Read and understand these instructions before installing and retain them for future reference.

This product is intended for installation in accordance with the National Electric Code and local regulations in the United States or
the Canadian Electrical Code and local regulations in Canada. Use indoors only. This product is not designed or approved for
use on power lines other than single-phase voltages between 100 – 277VAC, 50/60Hz. Attempting to use this product on non-
approved power lines may have hazardous consequences.

Recommended installation practices:
-

Use only indoors or in an outdoor rated box.

-

Be sure that you have turned off the circuit breaker or removed the fuse for the circuit you are installing this product into.
Installing this product with the power on will expose you to dangerous voltages.

-

Connect using only copper or copper-clad wire.

-

This product may feel warm during operation. The amount of heat generated is within approved limits and poses no
hazards. To minimize heat buildup, ensure the area surrounding the rear of this product is as clear of clutter as possible.

-

Each INSTEON product is assigned a unique INSTEON I.D., which is printed on the product’s label.

-

To reduce the risk of overheating and possible damage to other equipment, do not use this product to control Loads in
excess of the specified maximum(s) or, install in locations with electricity specifications which are outside of the product’s
specifications. If this device supports dimming, please note that dimming an inductive Load, such as a fan or transformer,
could cause damage to the dimmer, the load-bearing device or both. If the manufacturer of the load device does not
recommend dimming, use a non-dimming INSTEON on/off switch. USER ASSUMES ALL RISKS ASSOCIATED WITH
DIMMING AN INDUCTIVE LOAD.

Identifying the Electrical Wires in Your Home

-

Line – carries 100-277VAC electricity into the wall box, may also be called hot, live or power, commonly black

-

Neutral – returns 100-277VAC to power company, commonly white and in a multi-wire bundle

-

Load – connects to light/load device, commonly black and in a separate cable jacket

-

Ground – connection to electrical ground, commonly a bare wire, a green wire or a screw on a metal box

IMPORTANT!
If you have any difficulties or questions, consult an electrician. If you are not knowledgeable about and comfortable with electrical
circuitry, have a qualified electrician install the product for you.

Installation

Installation – Circuit with 1 Switch (a.k.a. 2-way circuit)

1)

At electrical panel, turn off circuit breaker(s) and/or remove fuse(s) feeding wall box. Verify that the
power is off before continuing

2)

Remove wallplate from the switch. Unscrew switch and gently pull out

3)

Disconnect wires from switch

1

4)

Turn on power

5)

Use a voltage meter to identify the line and load
wires connected to the switch

6)

Identify neutral and ground wires

7)

Turn off power

8)

Connect wires as per table/diagram (confirm firm
attachments with no exposed wire)

9)

With LEDs on left, gently place SwitchLinc into wall
box and screw into place

1

If the wires cannot be detached by unscrewing them, cut the wires where they enter the switch, then strip ½” of insulation off the ends

In the Box

Tools Needed

Optional Accessories

SwitchLinc Dimmer

Slotted and Phillips screwdrivers

INSTEON app

Quick Start Guide

Wire cutter/stripper

SmartLinc Hub

2 screws and 4 wire nuts

Voltage meter

SwitchLinc Wire

Wall Box Wires

Bare copper

Ground

(commonly bare

copper, green wire or

green screw)

White

Neutral

(commonly white)

Red

Load

(connected to light)

Black

Line

(277-100V to Ground)

Advertising