Insteon thermostat button overview – INSTEON Thermostat with Humidity (2441TH) Manual User Manual

Page 4

Advertising
background image

Page 4 of 28 Rev: 1/21/2014 8:35 AM

INSTEON Thermostat Sample

The gray buttons

are under the

INSTEON

Thermostat door

Cool setpoint

Heat setpoint

Time of day

state

Humidity level

Time

Current

temperature

Temperature of remote

sensors or zone thermostats

position 1 and position 2

(up to 2)

Current

thermostat

mode:

Off, Auto,

Heat or Cool

INSTEON Thermostat Button Overview





1) Up/Down buttons adjust the temperature setpoint based on the current mode.

2) Mode allows the user to select the current operational mode of the HVAC system. It cycles

among Off, Heat, Cool, Auto and Time of Day.

3) Energy (Leaf) button is designed as a quick access option that saves energy (and money). When

pressed, it will set back the setpoint by a specified value. The default value is 4° from the current
setting. To change the default offset value you must use software such as HouseLinc

TM

.

4) Hold overrides a preprogrammed mode to stay in the current settings mode.

5) Fan cycles between Auto and Always On – there is no indicator for Auto Fan.

6) Master makes this device the master temperature controller when you have one or more zone

thermostats. Pressing and holding “Master” does not alter any scene or screen settings; it just
defines this INSTEON Thermostat as the master temperature controller.

7) Time/Sensor allows you to set the day and time. It cycles among hour, minute, day and time

programming.

8) Program allows you to set up the various preprogrammed modes (Wake, Leave, Return and

Sleep). It also allows you to setup various features and calibrate the temperature and humidity.

9) Set is for adding and removing INSTEON Thermostat to and from INSTEON scenes. It functions

like the Set button on other INSTEON devices.

2

1

4

5

6

7

8

9