INSTEON Smoke Bridge (2982-222) Manual User Manual

Page 7

Advertising
background image

Page 7 of 14

2982-222 - Rev: 1/21/2014 8:34 AM

Remove Smoke Bridge as a Controller of Multiple Responders

1) Press and hold Smoke Bridge set button until it beeps

LED will start blinking green

2) Press and hold Smoke Bridge set button until it beeps again

LED will start blinking red

3) Tap Smoke Bridge set button

LED will start double-blinking red

4) For each responder you are removing:

a. Press and hold Set button until it double-beeps

5) Tap Smoke Bridge set button

Smoke Bridge will beep and LED will stop blinking

6) To test, first change the responder to a different state then the desired state
7) Test by tapping Smoke Bridge set button

The Set button will cycle through the following notifications with a brief delay between each

- Smoke detected

- Carbon Monoxide (CO) detected

- Low Battery detected

- Error

- All Clear

Smoke Bridge LED will blink red during these steps

~15 seconds after it sends the All Clear command, it will turn solid green

Responder will not respond