Adjust local settings, Insteon blink on traffic, Programming lock – INSTEON Smoke Bridge (2982-222) Manual User Manual

Page 9

Advertising
background image

Page 9 of 14

2982-222 - Rev: 1/21/2014 8:34 AM

Adjust Local Settings

INSTEON Blink on Traffic

Default = disabled

This setting is only adjustable via software or a central controller. Smoke Bridge LED will blink green if it
detects noise that could disrupt communication. It will blink red when it sees traffic to it from its paired
First Alert Smoke Alarm.

Programming Lock

Default = disabled

This setting is only adjustable via software or a central controller. When enabled, Programming Lock will
disable the Set button so that a user can not adjust settings or modify links. This is typically used in
commercial or installer applications.

Resetting Smoke Bridge to its Factory Default Settings

All settings and scenes will be erased, including the link between the First Alert Smoke Alarm and the
Smoke Bridge. To continue to use the Smoke Bridge with a First Alert Smoke Alarm, you must relink
them using the steps in “Pairing Smoke Bridge to First Alert Smoke Alarm” above.

1) Unplug Smoke Bridge to remove power
2) Wait 5 seconds
3) Press and hold Set button while plugging in Smoke Bridge. Do not let go.

Smoke bridge will emit a long beep

4) When long beep stops, release Set button

A few seconds will pass
Smoke Bridge will double-beep

5) Relink Smoke Bridge and First Alert Smoke Alarm

Advertising