CognitiveTPG A798 User Manual

Page 102

Advertising
background image

Chapter 4: Programming Commands

102

Revision C 12/09

A798-PG00001C

Return main program flash CRC

ASCII

GS SI

Hexadecimal 1D 0F

Decimal

29 15

Returns the CRC calculated over the flash firmware code space.
The format of the response is ACK <low byte> <high byte>.

Erase selected flash sector

ASCII

GS DLE n

Hexadecimal 1D 10 n

Decimal

29 16 n

Value and range of n:

0–7 = 512k bytes flash

0–15 = 1M bytes flash

0–31 = 2M bytes flash

Erases the previously selected sector. The printer transmits ACK when the sector has been erased. If the previous sector is
not successfully erased, or if no sector was selected, the printer transmits NAK.
Exceptions

Available only in download mode.

Download to active flash sector

ASCII

GS DC1 aL aH cL cH d1… dn

Hexadecimal 1D 11 aL aH cL cH d1… dn

Decimal

29 17 aL aH cL cH d1… dn

Value of aL:

low byte of the address

Value of aH:

high byte of the address

Value of cL:

low byte of the count

Value of cH:

high byte of the count

Value of d:

data bytes, 0–255

Value of n (for number of data bytes)

Range of address (aL aH)

Range of count (cL cH)

((cH * 256) + cL)

0000–FFFF (hexadecimal)

0001–FFFF (hexadecimal)

Range:

Addresses run from 0 to 64K.

Contains a start address (aH x 256 + aL) and count (cH x 256 + cL) of binary bytes to load into the selected sector,
followed by that many bytes. The start address is relative to the start of the sector. Addresses run from 0 to 64K.
The count must always be 256.
The printer may return one of several responses. ACK means that the data was written correctly and the host should
transmit the next block. NAK means that, for some reason, the data was not written correctly. This could mean that
communications failed or that the write to flash failed. The alternatives seem to be to retry the block or halt loading and
assume a hardware failure.
Related information

Available only in download mode.

Reset firmware

ASCII

GS (SPACE)

Hexadecimal 1D FF

Decimal

29 255

Ends the load process and reboots the printer. Before executing this command, the printer should have firmware loaded
and external switches set to the runtime settings. Application software for downloading should prompt the user to set the
external switches and confirm before sending this command. If the downloading was started from a diagnostic, the reboot
will cause the printer to re-enter download state unless the external switches are changed.