10 CVG-724xl Communication Protocol

This protocol includes two types of commands: 3 bytes and 4 bytes.

In the 3 bytes command type, the scaler operates in a fast mode because it does
not save the information immediately. The sent command is executed
immediately, but the status of the scaler is saved in the non-volatile memory only
after 30 sec of no activity.

In the 4 bytes command type, the scaler executes the save process immediately
after each command. This operation consumes more time (adding about 2 sec).

Set and Get command:
Set Command: Y Control_Type Function Param CR

Reply: Z Control_Type Function Param CRDone>CR

Get Command: Y Control_Type Function Param CR

Reply: Z Control_Type Function Param CR

Example:

1. "Y 1 17 0-127 CR" -> set Contrast value. (4th byte is between 0 and

127).

"Z 1 17 0-127 CR>" --> Reply value

"DoneCR" --> command setting success

2. "Y 4 21 0-17 CR" -> get current output resolution. (4th byte is

between 0 and 17).

"Z 4 21 0-17 CR>" -> Reply value

3. "Y 0 35 CR" -> Volume down. Each time we apply this command will

decrease the volume level by one step.

"Z 0 35 CR>"-->Reply value

"DoneCR" --> command setting success

Definition:

: ASCII Code 0x20

CR: Ascii Code 0xD or 0xA

After set type Command setting, system will respond a string as "Done"