Front panel, Mcn network note 1, Mcn network note 2 – CTI Products EXB-IP Ethernet System Extender User Manual

Page 10: Reset button, Mcn network connections, Csvc button identifies control processor, Ront, Anel, Figure 3 exb-ip module front panel

Advertising
background image

CTI Products, Inc.

EXB-IP User Guide

Introduction

10

F

RONT

P

ANEL












1

2

3

4

5

9

8

7

6

PWR

WINK

NETWORK

OUT

ASYNC

NETWORK

IN

ERR

CSVC

RSVC

RESET

ETH TX

ETH RX

ACT

Figure 3 EXB-IP module Front Panel

MCN Network Note 1

Unlike most other MCN modules, the EXB-IP module does not inject power into the Network Out connector. It
also does not use any DC power from the Network In connector. All 8 pins on the Network In & Out connectors
are paralleled, so that any power from other modules will be passed through.

MCN Network Note 2

Although the MCN Network connectors are RJ-45s, THEY ARE NOT ETHERNET CONNECTORS. Because
the MCN network connectors on the front of the modules may have DC power on them from other MCN devices,
DO NOT CONNECT THE NETWORK IN OR OUT CONNECTORS TO ETHERNET PORTS. THIS CAN
DAMAGE THE ETHERNET DEVICE. The Ethernet cable should be connected to the 10BASE-T connector on
the rear of the EXB module.

ETH TX LED Indicates when a packet has been

transmitted on the Ethernet port

WINK LED

Normally not used.
May be winked during Custom
Configuration to identify a unit.

ETH RX LED Indicates when a packet has been

detected on the Ethernet port

MCN NETWORK Connections

RJ-45 Normal Network connection.
Screw Terminals not normally used.

*** See MCN Network Notes 1 & 2***

ASYNC Connector

Used with PC running EXB Config
to access IP address parameters

RESET Button

Buttons for use with Custom Configuration
Press only when requested.

CSVC Button Identifies Control Processor
RSVC Button Identifies internal Router

PWR LED Indicates correct input power
ERR LED

Indicates an error condition
(see below)

ACT LED

Indicates MCN packet being
passed through unit.