Step 2. run exb config, Channel (file) name, Global ip subnet mask – CTI Products EXB-IP Ethernet System Extender User Manual

Page 18

Advertising
background image

CTI Products, Inc.

EXB-IP User Guide

IP Configuration – EXB Config

18

Step 2. Run EXB Config

To run the EXB Config program, click the “CTI EXB Config” icon on the desktop. The main window for EXB
Config is shown below.

Figure 5 EXB Config main window

Field Descriptions for Channel Global IP Parameters

Channel (file) Name
A Channel is defined as a collection of EXB-IP modules and their interconnecting IP network. Each system
will have its own Channel. Each MCN system could have multiple Channels (if, for instance, there were
multiple IP networks or if the system was split into multiple sub-systems.) The EXB Config software saves all
the information in a file using the Channel Name and an extension of .elp2. Channel Name will be shown as
“None” until the system has been saved for the first time.

Global IP Subnet Mask
A global IP Subnet Mask is entered if all modules (or most of the modules) use the same subnet mask. You can
use the Global IP Subnet Mask for individual modules so you don't have to type the subnet mask for each
module.

Add module member

Modules' UDP

Configuration file

Module

b

Variable

subnet

Modules' IP

EXB Config

Multicast group

IP

Configuration central site member

Com Port

l

i

Exb Config

H l

Disk IO options,

and printing

Advertising