Table E5

If the ACT LED (on local

EXB) . . .

REASON

CORRECTIVE ACTION

Occasionally blinks on, then

off.

Normal operation indicating a message

packet has passed through the router
module of the EXB.

Go to next Table.

Does not illuminate when

“RSVC” button on remote
EXB is pressed.

1. Router Service Pin message from

remote EXB is not reaching the local
EXB.

2. Router Service Pin message from

remote EXB is not passing through
the local router module.

1a. Verify that “ACT” and “ERR” LED’s on

remote EXB flash once. If not, return
remote module for evaluation/repair.

b. Verify that “ETH TX” LED flashes on the

remote EXB and that “ETH RX” LED
flashes on the local EXB.

2a. Place the remote router in Repeater mode

and verify that the local “ACT” LED
illuminates when “RSVC” button on
remote EXB is pressed.

b. If ‘2a’ is ok, re-program the router in the

local EXB.

c. If ‘2a’ is not ok, swap either the local or

remote EXB with a known-good-module
to determine the faulty module.

Does not illuminate when

other modules on the local
MCN network are
transmitting messages.

1. Message packets from modules on the

local MCN network are not passing
through the router in the local EXB.

1a. Verify the connection between the local

EXB and other modules on the MCN
network.

b. Place the router in the local EXB in

Repeater mode and verify that its “ACT”
LED illuminates when modules on the
local MCN network are transmitting
messages.

c. If ‘1b’ is ok, re-program the router in the

local EXB.

d. If ‘1b’ is not ok, return the local EXB

module for evaluation/repair.

Does not illuminate when

modules on a remote
MCN network are
transmitting messages.

1. Message packets from modules on a

remote MCN network are not passing
through the router in the remote
EXB.




2. Message packets from modules on a

remote MCN network are not
reaching the local EXB.

3. Message packets from modules on

remote MCN network are not passing
through the router in the local EXB.

1a. Verify the connection between the remote

EXB and other modules on the remote
MCN network.

b. Verify that “ACT” LED on remote EXB

illuminates when other modules on the
remote MCN network are transmitting
messages.

c. Place the router in the remote EXB in

Repeater mode and verify that its “ACT”
LED illuminates when modules on its
remote MCN network are transmitting
messages.

d. If ‘1c’ is ok, re-program the router in the

remote EXB.

e. If ‘1c’ is not ok, return module for

evaluation/repair.

2.

See this Table above and verify step “ACT
LED… Does not illuminate when RSVC
button on remote EXB is pressed”.

3.

See this Table above and verify step “ACT
LED… Does not illuminate”. when
“RSVC” button on remote EXB is
pressed”.