Receiver banks, Eceiver, Anks – CTI Products TIB TSAM Interface User Manual
Page 10
TIB Hardware Reference
Theory of Operation
CTI Products, Inc.
68-10911-100
5
3.4 Receiver
Banks
If the Comparator I/O Module that is associated with a TIB supports more than 8
receivers (it divides its receivers into multiple banks, as specified in the Receiver
Banks section of reference 1), then the TIB must be configured so that its
transmitters are associated with the proper receiver bank of the Comparator I/O
Module. This is done by setting the receiver bank selector switches (see section 4
for switch settings) on the TIB. Setting these switches configures the TIB’s 8
transmitters to correspond to the 8 receivers of the selected bank.
Because the CIB is the only Comparator I/O module the TIB operates with, the
TIB’s receiver bank selector switches must be set to bank 0.