Multi-unit Installations

Up to four AE-100 units may be connected to the same dedicated
telephone line to form a simple network. Connecting multiple units allows
transferring programming data (either the directory entries only or the
entire memory’s contents) from the “master” unit to the other sub-units
using the system utility commands.
In multi-unit installations each AE-100 must be assigned a unique unit
number before programming. The unit number allows connecting to a
specifi c unit when calling for programming and identifi es the other units
to the master unit. One unit must be assigned as “Master Unit #1”.

NOTE: If this is the only unit used in the installation, leave the factory

setting at one. Skip this programming section.

These programming steps can only be performed at the AE-100’s keypad,
they cannot be done remotely via the telephone. For each of the following
steps, enter the Master Password and enter Programming Mode (if the
unit is not already in that mode).

Setting Unit Numbers

Perform the following steps on each AE-100 unit connected to the
same telephone line
.

1. Press:

2. Enter the unit number (1-4). Make the master unit #1.
3. Press

Setting Sub-unit Numbers in the Master Unit

Perform the following steps on the master unit.

1. Press:

2. Enter the unit numbers of all of the sub-units:

In a two unit installation enter

In a three unit installation enter

In a four unit installation enter

To reset to a single-unit installation enter

(also be sure to set the unit number back to Unit #1)

NOTE: If one of the sub-units goes down for service or is removed from the

installation, notify service personnel to reprogram this step on the master
unit to remove the missing sub-unit. This will prevent errors when the master
unit tries to communicate with the missing sub-unit.

Changing the Master Password

Use this programming step to change the six-digit Master Password.
In multiple-unit installations each unit can have a unique Master
Password, but for simplicity and for easier service, it’s recommended to
use the same Master Password for each unit.

1. If not already in Programming Mode, connect by telephone or use the

keypad. Enter the Master Password and access programming.

2. Press:

3. Enter the new 6-digit Master Password.
4. Press
5. Enter the new 6-digit Master Password again.
6. Press
7. Write down the new Master Password here and on Page 3 of the

Facility Manager’s Guide.




PPN 01

01#PASS#PASS#

PASS = THE NEW 6-DIGIT MASTER PASSWORD

CHANGING THE MASTER PASSWORD

FACTORY SETTING: 123456

PPN 71

71#UNIT#

UNIT = UNIT NUMBER (1-4) FOR MULTI-UNIT INSTALLATION

SETTING A UNIT NUMBER

FACTORY SETTING: UNIT NUMBER 1

PPN 07

07#SUB-UNITS#

SUB-UNITS = EACH UNIT NUMBER (2-4) USED IN
A MULTI-UNIT INSTALLATION

SETTING SUB-UNIT NUMBERS

FACTORY SETTING: NONE

WRITE MASTER PASSWORD HERE

__ __ __ __ __ __

STANDARD PROGRAMMING METHOD

NOTE:

AFTER SETTING UP A MULTI-UNIT INSTALLATION WITH
THESE STEPS, WRITE IN THE UNIT LOCATIONS BELOW AND
ON PAGE 6 IN THE FACILITY MANAGER’S GUIDE TO INDICATE
TO THE FACILITY MANAGER THE UNIT NUMBERS ASSIGNED
AND THEIR LOCATIONS.

UNIT #

UNIT TYPE

UNIT LOCATION

1

MASTER UNIT

2

SUB-UNIT

3

SUB-UNIT

4

SUB-UNIT