FUNCTION CODE

LOCAL PROGRAMMING

TELEPHONE PROGRAMMING

74

AUTOMATIC

TELEPHONE

ANSWER

The factory setting will allow the
system to detect a ring signal on
the telephone line and answer
the call.

NOTE: The automatic answer
feature can be turned off,
although remote programming,
remote access control by
residents, and resident call-back
features will no longer function

Step 1 Enter Function Code 74, then press #.

Step 2 The display will show the auto answer setting.

Enter 0 to disable auto answer.
Enter 1 to enable auto answer (default).

Step 3 Press #.

NOT AVAILABLE

75

SPEAKER CHIRP

ON KEYSTROKES

The factory setting will cause
the speaker to chirp when each
key on the keypad is pressed.
Alternately, the speaker chirp can
be turned off.

Step 1 Enter Function Code 75, then press #.

Step 2 Enter 0 to turn the keystroke chirps OFF.

Enter 1 to turn the keystroke chirps ON (default).

Step 3 Press #.

Step 1 Enter Function Code 75 and

press #, one short beep sounds.

Step 2 Enter 0 to turn the keystroke chirps OFF.

Enter 1 to turn the keystroke chirps ON.

Step 3 Press #, two short beeps sound.

76

SPEAKER TONE

ON ACCESS RELAY

ACTIVATION

The factory setting will cause the
speaker to sound a tone for two
seconds when the access relay
is activated. Alternately, the tone
can be turned off.

Step 1 Enter Function Code 76, then press #.

Step 2 Enter 0 to turn the relay tone OFF.

Enter 1 to turn the relay tone ON (default).

Step 3 Press #.

Step 1 Enter Function Code 76 and

press #, one short beep sounds.

Step 2 Enter 0 to turn the relay tone OFF.

Enter 1 to turn the relay tone ON.

Step 3 Press #, two short beeps sound.

77

RESIDENT

CONTROL OF

ACCESS RELAY

The factory setting allows the
resident to activate the access
relay by pressing the 9 key on
their telephone when a call from
the AE-100 is received. This
feature can be disabled. Disabling
this feature will only allow access
by using resident Access Codes
and Stand-alone Access Codes
at the unit’s keypad.

Step 1 Enter Function Code 77, then press #.

Step 2 Enter 0 to disable resident control of the access

relay.
Enter 1 to enable resident control
of the access relay (default).

Step 3 Press #.

NOT AVAILABLE

A U T O - A N S W E R = 1 :

E N A = 1 D I S A = 0 :

B E E P O N = 1 O F F = 0

U N L O C K B E E P ( 1 , 0 )

ALTERNATE PROGRAMMING METHOD