The Model AE-100 Commercial Telephone Entry System is designed
for use as an access control device for small apartments or gated
communities with up to 125 residents. The system can be used in a
lobby or outside. Surface, recessed, and pedestal mounting options
are supported. The system utilizes hands-free, full duplex telephone
communications between visitors and residents for granting access.
Housed in a locked, rugged stainless steel faced enclosure, the AE-100
features a lighted 12-key telephone style keypad and four operation
buttons all with bright, easy-to-see graphics. The backlit two-line directory
LCD display scrolls a programmable welcome message and shows the
directory Names and Directory Codes. The system contains a built-in
microphone, tamper resistant speaker, and a TTY connector for the
hearing impaired.
The heavy duty access relay can control electric door strikes, magnetic
locks, door & gate operators, or barrier gates.
Multi-lingual display programming prompts and voice help is available with
a choice of English, Spanish, French-Canadian, or Portuguese language
selection for the system. The system can be programmed locally using
the keypad, or remotely with a touch tone telephone.
Instruction manuals and other support documents in Spanish,
French-Canadian, and Portuguese are available on the
Linear Web site’s AE-100 product page at www.linearcorp.com.
Optional features that the AE-100 supports are provisions for postal lock
and color CCTV camera installation.
The AE-100 is powered from a 16 VAC plug-in transformer and supports
an internal rechargeable 1.2 amp/hour backup battery (not included). The
battery charging circuit will support an external backup battery with up to
7 amp/hour capacity.

Before starting the installation, please read and understand these
instructions. Become familiar with the illustrations and wiring
diagrams. They will be a guide to installing the system in an effi cient
and professional manner.

Hardware Features

2-LINE, 16-CHARACTER-PER-LINE LCD DISPLAY

LED backlit display with easy-to-read .3” high characters

HEAVY DUTY FORM “C” (N.O. & N.C.) ACCESS RELAY

Relay has 10-amp AC & 7-amp DC @ 30 Volts rating

POSTAL SWITCH OPTION

Cabinet supports mounting a standard U.S.P.S. postal switch for
mail carrier access

BUILT-IN ANNUNCIATOR

Programmable for beeps during access and chirps during keystrokes

SMART BACKUP BATTERY CHARGING CIRCUIT

Automatic load shed disconnects the backup battery if battery
voltage drops too low

TTY JACK

Front panel connection for TTY text communications device for
the hearing impaired

OPTIONAL COLOR CCTV CAMERA

System supports a Model CCM-1 color CCD camera for viewing
the visitor area

FLEXIBLE TELEPHONE LINE CONNECTION

Telephone line can connect to on-board RJ-11 jack or terminal
block

REMOVABLE TERMINAL BLOCKS

All terminal blocks are removable for quick servicing

TRIM RING FOR RECESS MOUNTING

System can be mounted recessed using the optional Model
TR-100 trim ring

Software Highlights

AUTOMATIC DUAL PROGRAMMING METHODS

The system automatically recognizes two methods
of programming to aid installers already familiar with
programming other manufacturer’s access control systems

LOCALLY PROGRAMMABLE

All programming can be performed from the unit’s keypad

REMOTE TELEPHONE PROGRAMMING

Most programming can be performed with a TouchTone™
telephone over the phone line

125 RESIDENT DIRECTORY CAPACITY

Up to 125 residents can have a directory listing

125 STAND-ALONE ENTRY CODES

Up to 125 Stand-alone Entry Codes without a Directory Entry
can be used for gaining access (Each Stand-alone Entry Code
used reduces the number of available resident Directory Entries
by one).

4 DIGIT ENTRY CODE LENGTH

4-digit length for all Entry Codes

MANUAL ACCESS RELAY OPERATION

Access relay can be activated indefi nitely or for a set period of time

2-3 DIGIT DIRECTORY NUMBER LENGTH

Directory Number lengths can be customized for small or large
installations

MULTIPLE UNIT SUPPORT

Up to four AE-100 units can be connected to the same
telephone line and share programming data using system utility
commands.

RESIDENT CALL-BACK SUPPORT

Residents can call the system to initiate 2-way communications
with a visitor. (Single unit installations only.)

Introduction ............................................... 2
Hardware Features ................................... 2
Software Highlights ................................... 2
Feature Overview ..................................... 3
Operation .................................................. 3
Database Overview .................................. 3
Component Locations ............................... 4
Wiring Diagram ......................................... 5
Important Mounting Requirements ........... 6
Entry System Mounting ............................ 7
Entry System Mounting (Continued) ......... 8
Access Relay Wiring ................................. 9
Telephone Wiring ...................................... 9
Multiple Unit Telephone Wiring ............... 10
Power, Battery, & Ground Wiring ............ 11
Optional Postal Lock ............................... 12
Optional Color CCTV Camera ................ 12
Programming Reference & Factory
Defaults .................................................. 13
Access to Programming ......................... 14
Programming from the Keypad (Standard
Method) .................................................. 14

Programming Over the Telephone .......... 15
Multi-unit Installations ............................. 16
Changing the Master Password ............. 16
Resident Data Programming .................. 17
Stand-alone Entry Code Programming ... 18
System Options ...................................... 18
System Options (Continued) .................. 19
System Options (Continued) .................. 20
System Utility Commands ...................... 21
System Utility Commands (Continued) ... 22
Alternate Programming Section .............. 23
Alternate Programming Reference ......... 24
System Adjustments ............................... 32
System Diagnostics ................................ 32
AE-100 Operation ................................... 33
Specifi cations ......................................... 34
Dimension Drawing ................................ 34
Accessories ............................................ 34
Troubleshooting ...................................... 35
Linear Limited Warranty.......................... 35
FCC Notice ............................................. 35

Advertising