Push

ENTER

. Then push

MENU (NEXT)

until the

System Power menu appears on the status display.



Push

ENTER

. The display will show the current

power configuration. For example:


Use the and buttons to select a configuration
corresponding to the actual power being supplied to
the AR-1202. Push

ENTER

when correct power is

shown. The available choices are shown below.

AR 1PhsN Single Phase 120/240V Power Source
AR 3PhsN 3 Phase 120/208V Power Source

Normal Phase Rotation

AR 3PhsR 3 Phase 120/208V Power Source

Reverse Phase Rotation

There are two additional settings which are used only
when it is not possible to provide actual 120/240V
Single Phase power and the unit is being powered by
2 phases of a 120/208V 3 Phase source.

AR 2PhsN 2 Phase 120/208V Power Source

Normal Phase Rotation

AR 2PhsR 2 Phase 120/208V Power Source

Reverse Phase Rotation

NOTE: There are 2 other settings available in this
menu. These do not apply to the AR-1202 dimmer.

You may not know in advance if you should use the
Normal or Reverse rotation choice for 3 phase or 2
Phase power. If this is the case then use

NORMAL

phase rotation

.

NO damage will occur if the rotation is actually
reversed but dimming will not occur correctly and
some channels will appear to be in a on/off mode.
This will be readily apparent when operating the unit.
You can then change the setting.

UNIT ADDRESS ASSIGNMENT

When using a single AR-1202 unit system, the unit
address MUST BE SET TO

00

. One (and only one)

of the units in a multiple unit system must be set to
address

00

. Other units should be assigned in a

consecutive order.

At the AR-1202 front panel - push

MENU (NEXT)

until the

System Setup

appears on the status display.


Push

ENTER

. Then push

MENU (NEXT)

. The System

ID Set menu will be shown.


Push

ENTER

. The display shows the unit address.



Set the desired address by pushing the and buttons.

Push ENTER

. Then push

CLEAR

to return to the

normal operating mode.

DIMMER CHANNEL SETUP

Individual channels within the AR-1202 dimmer can
be set for different behaviors. Any channel may be
limited to a user selected maximum intensity level.
Limiting applies to manual, scene, and DMX
operation. Any channel may also be set to run as
NON-DIM (or RELAY).

CHANNEL LIMITING

At the AR-1202 front panel - push

MENU (NEXT)

until the Dimmer Setup menu appears on the display.




Push

ENTER

. The Channel Limit menu will be

shown.



Use the and buttons to select a channel. Then
use the and buttons to set its limiting value.
Push

ENTER

when finished. The limit range on the

menu is between 10 and 255 which corresponds to
lighting intensity of between 4 and 100 percent.



SYSTEM

POWER

SYSTEM
AR 3PhsN

SYSTEM

ID SET

SET UNIT
ID 00

DIMMER

SETUP

01 LMT

255

SYSTEM

SETUP