AR – 1202

RTC

ARCHITECTURAL DIMMER

Revision

1.93

OWNERS

MANUAL 06/03/2008

www.lightronics.com

Lightronics Inc.

509 Central Drive Virginia Beach, VA 23454

Tel 757 486 3588


SIMPLE REMOTE CONNECTIONS





Scenes 1 - 7 (stored in the AR-1202) may be used by
simple remotes. A BLACKOUT function may also be
accessed. A simple remote is any switch which can
provide a momentary contact closure which can be
applied to a specific pin on the AR-1202

SIMPLE

REMOTE CONNECTIONS terminal strip

.

The SIMPLE REMOTE COMMON is routed to the
remote switch.


When the switch is operated the closure brings the
common back to the applicable simple remote scene
number connection point at the AR-1202 terminal
strip. Almost any available low voltage wire may be
used since these connections are just contact closures.

Multiple simple remotes may be used. Additionally
multiple AR-1202 units may be chained to one or
more simple remotes

See the diagram "EXTERNAL CONNECTIONS" and
the example below for specific connection
information.















AR - 1202 UNIT SETUP


















CAUTION

REMOVE ALL POWER FROM THE AR-1202

BEFORE MAKING OR CHANGING SIMPLE

REMOTE CONNECTIONS.

FRONT PANEL (PARTIAL VIEW)

POWER

D

MENU

(NEXT)

CLEAR

ENTER

Menu/Status

Display

1 2 3 4 5 6 7 8 9

Simple Remote

Common

Simple Remote

Connections

Terminal Strip

Simple Remote

APP01

Scene 8 (Blackout)

Scene 1

SIMPLE REMOTE CONNECTIONS EXAMPLE USING A LIGHTRONICS APP01