Warning – MAX SN883RH2 User Manual

Page 12

Advertising
background image

12

SWITCHING SINGLE ACTUATION TO

CONTACT ACTUATION WITH ANTI-

DOUBLE FIRE MECHANISM

ALWAYS disconnect air supply before

switching the triggering method.

1

Gently push out the Spring Pin which indicat-
ed with " T " mark straight with the punch or
similar tool.

2

Remove the Switching Lever to the direction
of the arrow.

NOTE:
When switching back CONTACT ACTUATION
with ANTI-DOUBLE FIRE MECHANISM to SIN-
GLE ACTUATION, equip the Switching Lever
facing "D" mark front with the Spring Pin to the
Trigger by reverse procedure.

Trigger

Punch

Spring Pin

WARNING

Spring Pin

Switching Lever

SN883RH2_SN890CH2(34).book 12 ページ 2011年7月8日 金曜日 午後6時1分