level in the transmission is ½ of a quart low, the FILL button should be pressed once. The light above the ½
qt. indicator will light. This amount of fluid will automatically be added to the transmission during the
service. The alternative action would be for the technician to add the correct amount of fluid manually to the
transmission, before starting the service.

If pressed after DRAIN mode, the unit will add the amount of fluid entered according to the lights that are
lighted under the FILL button (see chart in this section).

EXAMPLE: When the transmission fluid pan is to be removed, the technician will press the DRAIN button,
the unit will empty fluid until the filter cannot pull any from the pan. Once the pan is removed there will be
some fluid left at the bottom of the pan, this fluid is emptied manually into the shop’s recycling container.
When this happens, the machine will not account for the fluid that was removed manually. The technician
should calculate the amount of fluid removed manually, then press the FILL button according to the amount
calculated.

If pressed when the COMPLETE light is ON, but the LOW CLEAN FLUID light is OFF,

First press,

the pump will run continuously. Second press, ½ qt. light will turn on, the unit will add half of a quart and
stop automatically. Press three times, the 1 qt light will turn on and the unit will add one full quart and stop
automatically etc,. See chart below.


FILL- ADDITIONAL FLUID COUNT LIGHTS:

First light on = 1/2 qt.


Second light on = 1 qt.

First and second lights on = 1 ½ qts.

Third light on = 2 qts.

Third and first lights on = 2 ½ qts.

Third and second lights on = 3 qts.

All lights on = 3 ½ qts. / Maximum fluid added automatically.

Pressing the Fill button once more will turn all lights off.





LOW CLEAN FLUID:

• The light will be on when the CLEAN FLUID tank is empty.

COMPLETE:

• The COMPLETE light will turn on when clean fluid tank is empty or the STOP button is pressed. The unit