Appendix a: monitor arming commands – American Dynamics ADCC1100 User Manual

Page 49

Advertising
background image

43

Keyboard Installation and Operation

Appendix A: Monitor Arming Commands

Monitors are armed for alarm call up with codes that specify the following three parameters:
1. The display method (single, dual, or block monitors).
2. The queuing method (sequence or hold).
3. The clearance method (instant, auto, or manual).
To arm a monitor with an ADCC1100 keyboard:
1. Call the monitor to be armed.
2. Press the PROGRAM MODE tab key.
3. Enter the monitor arming code number (see table).
4. Press the F2 soft key.
A keyboard operator can also program any monitor armed for instant or auto clearance, for clearance via manual

override. Manual override is enabled or disabled after the arming code is programmed. If enabled, an "A" will appear

after the three-letter acronym for the arming code that appears on the monitor status line.
When using the AD1024 matrix switcher/controller system, monitors can be armed through system setup software

with a PC interface, or through the AD1024 embedded software with an ADCC1100 keyboard. Following is a table of

monitor arming codes and the commands that enable the codes.

* In dual display applications, the first three-letter acronym is displayed on the hold monitor. The second three-letter

acronym is displayed on the sequence monitor.

Monitor Arming Code

Monitor Acronym

Command Sequence

Display Arming Status

see entries below

300, F2

Single, Sequence, Instant

SSI

301, F2

Single, Sequence, Auto

SSA

302, F2

Single, Sequence, Manual

SSM

303, F2

Single, Hold, Instant

SHI

304, F2

Single, Hold, Auto

SHA

305, F2

Single, Hold, Manual

SHM

306, F2

Block, Sequence, Instant

BSI

307, F2

Block, Sequence, Auto

BSA

308, F2

Block, Sequence, Manual

BSM

309, F2

Block, Hold, Instant

BHI

310, F2

Block, Hold, Auto

BHA

311, F2

Block, Hold, Manual

BHM

312, F2

Dual, Hold, Instant

DHI/DSI*

313, F2

Dual, Sequence, Instant
Dual, Hold, Auto

DHA/DSA*

314, F2

Dual, Sequence, Auto
Dual, Hold, Manual

DHM/DSM*

315, F2

Dual, Sequence, Manual
Disarm Monitor

316, F2

Enable Monitor Override

317, F2

Disable Monitor Override

318, F2

Advertising