Optional equipment adjustments – Poweramp POWERHOLD SC SERIES User Manual

Page 30

Advertising
background image

OPTIONAL EQUIPMENT ADJUSTMENTS

Whenever the platform lip is at the full below-dock
position, the following conditions will exist for a
normally operating ARTD:

• Proximity switch senses target.

• Proximity switch ON (closed) (signal sent to the

control panel).

• Proximity switch indicator light is ON.

• Platform will automatically rise after approximately

a six-second delay, then returns to the cross-traffic
position.

Full Below-Dock Position

Whenever the platform lip is at the fully extended
position, the following conditions will exist for a
normally operating ARTD:

• Target not in the sensing area of proximity switch.

• Proximity switch OFF (open) (no signal sent to the

control panel).

• Proximity switch indicator light is OFF.

• If the platform lip is resting on the truck bed, the

platform will stay at this position unless the
operator activates the leveler.

Lip Fully Extended Position

Lip Keeper

4111-0016 — Sept 2010