Trouble shooting powerhold – Poweramp POWERHOLD SC SERIES User Manual

Page 32

Advertising
background image

TROUBLE SHOOTING POWERHOLD

Symptom

Possible Cause

Solution

Three-phase units only:
Restraint does not
operate. Motor energizes
but does not run.

If motor hums, but does
not run, overload device
should trip.

Combination Leveler
and P-Hold Only.

3 Phase units only - no
voltage is present on one
line.

NOTE: A motor that is
missing voltage on one line
is said to be single-phased.

Check for blown fuses at branch circuit disconnect.
Replace fuse. Determine cause of blown fuse.

Check motor starter as follows:
1. Disconnect wires at load side of starter.
2. Energize the starter.
3. Measure line-to-line voltage at line side of starter.
4. Measure line-to-line voltage at load side of

starter.

5. Line-side and load-side voltages should be

approximately the same. Replace starter if
voltage values are considerably different from
one another.

Check all wiring to motor for high resistance or no
connection.

Replace motor.

Three-phase units only:
Restraint does not
operate. Motor runs in
reverse

Phase reversed.

Reverse any two legs at the branch circuit
disconnect.

Single-phase units only:
Restraint does not
operate.

Motor energizes, but
does not run.

Line voltage too low.

Check wiring to motor for high resistance. Check for
loose or corroded connections. Check if gauge of
wires to motor are of correct size and specification
for load requirement. Replace if necessary.

Defective motor centrifugal
switch.

Replace motor.

Defective motor capacitor.

Replace motor.

Low hydraulic fluid.

Add fluid, see Maintenance section for proper fluid
level and type.

Restraint operates
slowly.

Low hydraulic fluid.

Add fluid, see Maintenance section for proper fluid
level and type.

Pressure relief valve set too
low.
(combination unit only)

See pressure relief adjustments on page 48.

NOTE:

The pressure relief valve must not be set at a
level that causes the motor operating current to
exceed the full load amp value* at any time,
including when operating in pressure relief.

* The full load amp value can be found on the inside cover of the

control panel.

Power Hold raises Slow or
Slow to release
(SC Power Hold Only)

-Pressure Relief cartridge adjusted per max amp

draw.

Damage or blocked hydraulic
hose(s) and/or valve(s).

Replace damaged hose(s). Check and remove
blockage from hose(s) and/or valve(s).

4111-0016 — Sept 2010

30

Advertising
This manual is related to the following products: