11. MAINTENANCE INSTRUCTIONS

11.1 Crank mechanism maintenance.

Check oil level at least on a weekly basis (Fig. 8).

If necessary, add the missing oil through the oil plug

(position 1, Fig. 8). Check oil level when the pump is at

room temperature. When changing the oil (removing the

plug position 3, Fig. 8), the pump should be at its work-

ing temperature.

Change oil every 1000 working hours, oil pump capacity

is 2 litres.

In any case the oil should be changed at least once

a year, since oxidation deteriorates it.

Mineral or synthetic oils can be used but they must be

chosen according to the working environment

temperature. Here below is a diagram indicating viscosity

according to room temperature.

List of recommended oils:

GENERAL PUMP

RECOMMENDS

USING SAE 50W

BRAND

TYPE

GENERAL PUMP

SERIES 220

ARAL

Aral Degol BG220

BP

ENERGOL HLP 220

CASTROL

Hyspin VG 220, Magna 220

ELF

POLYTELIS 220

ESSO

NUTO 220

FINA

Cirkan 220

FUCHS

RENOLIN 220

MOBIL

DTE OIL BB

SHELL

TELLUS C 220

TEXACO

RANDO HD 220

TOTAL

CORTIS 220