7. GENERAL INFORMATION ABOUT PUMP

USE

The HF pump has been designed to pump fresh filtered
(360 micron max) water at room temperature (400 C max).

7.1 Water temperature

Water temperature is critical for the pump life, the higher it

is, the more likely it is to create cavitation, resulting in

premature seal and valve failures.

For such conditions, use HT series

pumps.

7.2 Pump performances

The performance data indicated in the catalog and on the

rating plate refer to the maximum performance of the

pump. The use of the pump below the rated performances

does not allow the drop in power absorbed to be balanced

by altering the pressure or volume of the pump above its

maximum value unless especially authorized by our

technical department.

7.3 Lowest operating RPM

The lowest operating speed for all HF’s (all versions)

is 500 RPM (on crankshaft).

8. CONNECTIONS AND PLUGS

HF pumps are provided with (Fig. 3):

1 - 2 inlet ports IN Ø 1” NPT

Either inlet port can be used; the one not used must

be hermetically plugged.

2 - 2 outlet ports OUT Ø 3/4” NPT