GENERAL PUMP

A member of the Interpump Group

HF SERIES

Page 16

Valve components of each valve are pressed together

and therefore they can be easily replaced and installed

back in place by means of simple tools (see Fig. 22).

Check the components for wear and replace if necessary.

Replace all o-rings of the valve units and valve plugs,

at each inspection.

IMPORTANT NOTE:

BEFORE REPOSITIONING THE VALVE

UNITS AND O-RINGS, CLEAN AND

PERFECTLY DRY ALL VALVE HOUSINGS

INSIDE THE FLUID END

(see arrows Fig. 23).

D) To reassemble the valves proceed the other way

around and tighten the cover screws with a

torque wrench. Table on page 18

contains the screw tightening torque

values and Fig. 28 (page 17) indicates

the sequence.

11.2.2 Seals

The replacement of the seals is necessary when water

drips throught the holes provided underneath the

crankcase. For replacement, do as follows:

A) Remove the fluid end by loosening the 8 bolts

(see Fig. 24).

B) Remove the high pressure packings from the fluid

end and the low pressure ones from their support

by means of standard tools, taking great care not to

damage the seats. See Fig. 25.