11.2.4 Fluid End

In order to mount the fluid end on the pump proceed

as follows:

A) Fit the packing supports back in place in the

crankcase.

B) Fit the pressure packings back in place in the pump

head.

C) Using two stud bolts (min. length: 200 mm) and the

central plunger as a guide carefully slide to head in

position against the crankcase.

D) Tighten the head bolts with a torque wrench set as

indicated in the chart to the right.

12. TORQUE SPECIFICATIONS

The following table contains the screw

tightening torque values, to be set by

means of a torque wrench only:

13. MAINTENANCE TOOLS

Standard tools are required for the pump maintenance

but to facilitate the mounting and dismounting operations

of some pump components, you will find the drawings

to make some tools on page 23.

DESCRIPTION

Ft. Lbs.

N-m

Kgm.

Rear cover

screws

7.3

10

1

Plunger Bolts

14.7

20

2

Connecting Rod

Screws

28

38*

4

Valve Plate

Screws

88.5

120**

12

Fluid End Bolts

59

80***

8

Auxiliary Plug

29.5

40

4

*

The conrod screws must be tightened as

indicated in point D, page 13.

** The valve plate must be tightened following

the sequence indicated in fig. 28.

*** The fluid end screws must be tightened in 2

stages following the sequence indicated in

fig 24:

First stage: 20 N-m

Second Stage: 80 N-m