Hf series, General pump – General Pump HF Owner Manual User Manual

Page 17

Advertising
background image

GENERAL PUMP

A member of the Interpump Group

HF SERIES

Page 17

Take note of the correct order of the entire package

components when disassembling (Fig. 26):

1. Head ring

2. HP packing

3. “Restop” ring

4. Middle ring

5. LP packing

6. Back packing

7. Elastic ring

8. O-ring

When reassembling, make sure of the correct order of

the components.

C) Reassembling:

In order to carry out the replacement more easily,

apply a very small quantity of silicone grease on the

pressure packing lips and their seats in the fluid end.

This operation will also help the sealing lips settle

on the plunger.

Fit the fluid end back in place and tighten the bolts

with a torque wrench set for the value

indicated in the table on page 18 and in the

sequence indicated here below.

11.2.3 Plunger

To replace the plunger, if necessary, do as follows:

A) Loosen and remove the plunger screws as

indicated in Fig. 29

When disassembling the pumping unit, the O-rings

should always be replaced.

B) Fit back the replaced components inverting the

order. Use a torque wrench set for the values

indicated in the table on page 18.