Vf series, General pump – General Pump VF Owner Manual User Manual

Page 10

Advertising
background image

GENERAL PUMP

A member of the Interpump Group

VF SERIES

Page 10

9.6 Suction Line (continued)

11. The pressure gauge for checking booster pressure

must be installed near the plunger pump’s outlet port, and

always after the filters.

9.7 Filtering

The filtration degree for these pumps must be max. 20

micron; this is normally obtained by means of a series of

at least three filters, positioned as indicated in fig. 7.

The filter must be installed as close as possible to the

pump, should allow easy inspection and have the

following characteristics:

1. Minimum capacity 3 times greater than the pump’s

rated flow value.

2. Filter port diameters must not be smaller than the

pump inlet ports.

3. Filtration degree:

Filter No. 1: 250 micron

Filter No. 2: 100 micron

Filter No. 3: 20 micron.

In order to guarantee correct pump operation,

it is important to plan periodical cleaning of

the filter depending on actual pump usage,

water quality and real clogging conditions.

In order to guarantee the required feeding

pressure (see paragraph 9.5), install a

pressure switch.

9.8 Delivery Line

To obtain a correct delivery line, please comply with the

following installation instructions:

1. The internal diameter of the pump must allow to guar-

antee correct fluid speed; see diagram in paragraph

9.9

2. The first section of the hose connected to the pump

must be flexible in order to isolate pump vibrations

from the rest of the system.

3. Use high pressure hoses and fittings that guarantee

wide safety margins in any working condition.

9.8 Delivery Line (continued)

4. Install a safety valve on the delivery line.

5. Use pressure switches suitable for the pulsating loads

typical of plunger pumps.

6. In the design phase, take into proper account the

pressure drop along the line, since this causes a

reduction in usage pressure with respect to the value

measured at the pump.

7. If the pump pulsations are harmful for particular appli-

cations, install an appropriately sized pulsation damp-

ener on the delivery line.

9.9 Internal Diameter of the Hose Line

To determine the internal diameter of the hose, please

refer to the following diagram.

Suction Hose

With a flow rate of ~4 GPM (15 l/mn) and water speed of

0.5 m/sec. the diagram line that connects the two scales

intersects the central scale, indicating the diameters, at a

value of ~ 25 mm (1 inch).

Delivery Hose

With a flow rate of ~4 GPM (15 l/mn) and water speed of

5.5 m/sec. The diagram line that connects the two scales

intersects the central scale, indicating the diameters at a

value of ~ 8 mm (.31 inch).

Optimum speed values:

• Suction:

≤ 0.5 m/sec.

• Delivery:

≤ 5.5 m/sec.

Ref 300662 Rev.C

06-12