7.INFORMATION ABOUT PUMP USE

The VF pump has been designed to operate

with filtered water (see paragraph 9.7) and at

room temperature.

Other fluids may be used only upon the

approval of The Customer Service

Department

.

7.2 Max Flow Rate and Pressure Values

The performance values indicated in the catalog refer to

the maximum performance of the pump. Regardless of the

power used, pressure and maximum RPM values indicat-

ed on the plate may not be exceeded unless expressly

authorized by the Customer Service Department.

7.3 Lowest RPM

Any RPM value different from what is indicated in the

performance table (see chapter 5) must be expressly

authorized by the Customer Service Department.

7.4 Recommended Lubricant Oil Types & Manufacturers

The pump is delivered with lubricant oil, compliant with
room temperatures ranging between 0

0

and 30

0

C (32

0

and 89.6

0

F). Some recommended lubricant types are

indicated in the table below; these lubricants are treated

additives in order to increase corrosion protection and

resistance to fatigue. As an alternative, Automotive SAE

85W-90 gearing lubricants may also be used.

7.1 Water Temperature

The max water temperature is 30

0

C (86

0

F)

BRAND

TYPE

GENERAL PUMP

SERIES 220

ARAL

Aral Degol BG220

BP

ENERGOL HLP 220

CASTROL

Hyspin VG 220, Magna 220

ELF

POLYTELIS 220

ESSO

NUTO 220

FINA

Cirkan 220

FUCHS

RENOLIN 220

MOBIL

DTE OIL BB

SHELL

TELLUS C 220

TEXACO

RANDO HD 220

TOTAL

CORTIS 220

Check the oil level by using the appropriate oil level dip-

stick with minimum and maximum value notches (1), fig. 3.

Refill if needed. Correct oil level inspection is done with the

pump at room temperature; oil is changed with the pump at

working temperature, by removing the rear plug (2), fig 3.

Oil is to be changed every 1000 hours of operation. The

amount required is ~128.5 oz. (3.8 liters).

In any case, oil must be changed at least

once a year since it may deteriorate by

oxidation.

For room temperatures that differ from that men-

tioned earlier, follow the indications contained in

the diagram below, keeping in mind that the oil

must have a minimum viscosity of 180 cSt.

Exhausted oil must be collected in an

appropriate receptacle and disposed of in

appropriate locations. In absolutely no case

may it be dispersed into the environment.

VISCOSITY/ROOM TEMPERATURE DIAGRAM

Ref 300662 Rev.C

06-12