Vf series, General pump – General Pump VF Owner Manual User Manual

Page 11

Advertising
background image

GENERAL PUMP

A member of the Interpump Group

VF SERIES

Page 11

The diagram does not take into consideration the

hose and valve resistance, the pressure drop due

to the hose length, the viscosity and the tempera-

ture of the pumped fluid. If necessary, contact our

Customer Service Department.

9.10 V-belt Transmission

The pump may be driven by a v-belt system. For this

pump model, we suggest to use 4 XPB belts (16.5 x 13

cogged); only for long durations, use the XPC profile; both

the characteristics and the power transmission capacity of

each belt can be verified on the diagram in fig. 8, in func-

tion of the number of rotations normally declared by the

Manufacturer. Minimum diameter of the driven pulley (on

the pump shaft): ≥ 250 mm. The radial load on the shaft

must not be greater than 7500 N (value required for the

definition of the lay-out). The transmission is considered

adequate if this load is applied at a maximum distance of

40 mm from the shaft shoulder (PTO) as indicated in fig.

11.

For sizing that differs from that indicated above,

please, contact our Customer Service

Department.

9.11 Transmission Definition

To avoid abnormal radial loads on the shaft and its related

bearing, please comply with the following indications

a) Use pulleys for v-belts with race dimensions

prescribed/ recommended by the belt Manufacturer.

Should no indications be supplied, please see fig.

9 and the table in fig. 10.

fig. 9

Dimensions (in mm)

fig. 10

2) Use high efficiency belts - for example XPB instead of

SPB; this will allow to use a lower number of belts to

transmit the same power, and consequently a minor

distance of the resultant from the shaft shoulder

(PTO) “a” in fig. 11.

fig. 11

Ref 300662 Rev.C