1. INTRODUCTION

This manual describes the use and maintenance

instructions of the VF pump, and should be carefully read

and

understood

before

using

the

pump.

Correct use and adequate maintenance will guarantee the

pumps trouble-free operation for a long time. General

Pump declines any responsibility for damage caused by

misuse or the non-observance of the instructions indicated

in this manual.

Upon receiving the pump, check that it is complete and in

perfect condition.. Should anything be found out of order,

please contact us before installing and starting the pump.

3. SAFETY

3.1 General Safety Indications

The misuse of pumps and high pressure units may

cause severe injury to people and/or damage to prop-

erty. Anyone requested to assemble or use high pres-

sure units must possess the necessary competence to

do so, should be aware of the characteristics of the

components assembled/used, and must adopt all the

necessary precautions in order to guarantee maxi-

mum safety in any operating condition. In the interest

of safety, no precaution that is reasonably feasible

must be neglected, both by the Manufacturer and the

Operator.

3.2 High pressure unit safety requirements

1. The pressure line must always be equipped with a

safety valve.

2. High pressure unit components, in particular

for those units working outside, must be adequately

protected against rain, frost and heat.

3. The units electrical parts must be adequately

protected from water spray, and must comply with the

specific norms in force.

4. High pressure hoses must be correctly sized for the

units maximum operating pressure, and must only be

used within the pressure range indicated by the hose

manufacturer. The same conditions apply for all other

unit accessories where high pressure is involved.

5. The extremities of high pressure hoses must be

sheathed and fastened to a steady structure in order

to avoid dangerous whiplashes should they burst or

should their connections break.

6. Appropriate safety guards must be provided for the

pump transmission systems (joints, pulleys and belts,

auxiliary drives).

3.3 Safety During Operation

The working area of a high pressure system must be

clearly signalled. Access must be prohibited to non-

authorized personnel and, if possible, the area must

be fenced in. The personnel authorized to access this

area must be previously trained, and informed about

the risks that may arise from failures or malfunctions

of the high pressure unit.

Before starting the unit, the operator must check:

1. That the high pressure unit is correctly fed (see

paragraph 9.5).

2. SYMBOL DESCRIPTIONS

Warning

Potential Danger

Danger

Electrocution Danger

Danger

Use Protective Mask

Danger

Use Protective Goggles

Danger

Wear protective gloves

Danger

Wear protective boots

Read carefully and understand

the manual before operating

the pump