SECTION 11 ROOM THERMOSTAT INSTALLATION

CAUTION: HAZARD OF ELECTRICAL SHOCK

11.1 All wiring must comply with the National Electrical Code, State and Local

Ordinances, and be wired by a qualified electrician.


11.2 Install the room thermostat in accordance with the directions furnished with

the thermostat.


11.3 Use two conductor thermostat wire for the connection of the thermostat to

the T.T. terminals of the oil primary control that is mounted on top of the
burners electrical box.


11.4 Mount the thermostat 5 feet above the floor on an inside wall away from the

heater’s warm air path.


11.5 The electrical current for thermostat is 24 V, and is provided by the oil

primary control.


11.6 Keep the thermostat wire away from the chimney connector, or any other

hot surfaces. Refer to Section 3.1 for a typical thermostat installation.