Supplemental trouble shooting guide continued – Lanair HI140 User Manual

Page 61

Advertising
background image

Supplemental Trouble Shooting Guide Continued

Symptom

Possible Cause

Corrective Action


A. Burner will not start.

1. Main electrical power

1. Reset Breaker.

circuit breaker tripped.


2.

Service

disconnect 2.

Turn

switch

on

or

switch

off

or

fuse blown.

replace fuse.


3.

Thermostat

turned

down/ 3.

Turn

thermostat

up,

improperly

installed/

check wires/test

defective.

components/replace.


4.

Oil

primary

safety

4.

Reset/test

components,

tripped/defective.

replace if needed.

5. Too much light showing

5. Eliminate light to cad

on

cad

cell/defective.

cell. Test component.


6.

Fan/Limit

control

reached

6. Check fan/limit control

. high/limit, or is defective settings (See page

13B) or test components.


B. Burner attempts to

1. Low oil in supply tank or

1. Fill tank, or drain and

fire, but does not

contaminated fuel.

clean tank.

establish a flame.

2.

Plugged

or

worn

nozzle.

2.

Clean

or

replace.


3.

Fuel

pressure

gauge

3. See section 7, Page 12.

fluctuating/pumping

system.


4.

Preheater

switch

is

turned off 4. Turn switch on or test

off or defective, or defective switch and cartridge

cartridge

heater.

cartridge heater.


5.

Transformer/electrodes

not

5. Test transformer/look

sparking.

for shorts & repair.

Replace

electrodes/

transformer.


6.

No

air

pressure/defective

6. Turn compressor on/test

regulator/defective

solenoid. regulator/solenoid.

Replace defective
components.

Page 45