Supplemental Trouble Shooting Guide Continued
Symptom
Possible Cause
Corrective Action
A. Burner will not start.
1. Main electrical power
1. Reset Breaker.
circuit breaker tripped.
2.
Service
disconnect 2.
Turn
switch
on
or
switch
off
or
fuse blown.
replace fuse.
3.
Thermostat
turned
down/ 3.
Turn
thermostat
up,
improperly
installed/
check wires/test
defective.
components/replace.
4.
Oil
primary
safety
4.
Reset/test
components,
tripped/defective.
replace if needed.
5. Too much light showing
5. Eliminate light to cad
on
cad
cell/defective.
cell. Test component.
6.
Fan/Limit
control
reached
6. Check fan/limit control
. high/limit, or is defective settings (See page
13B) or test components.
B. Burner attempts to
1. Low oil in supply tank or
1. Fill tank, or drain and
fire, but does not
contaminated fuel.
clean tank.
establish a flame.
2.
Plugged
or
worn
nozzle.
2.
Clean
or
replace.
3.
Fuel
pressure
gauge
3. See section 7, Page 12.
fluctuating/pumping
system.
4.
Preheater
switch
is
turned off 4. Turn switch on or test
off or defective, or defective switch and cartridge
cartridge
heater.
cartridge heater.
5.
Transformer/electrodes
not
5. Test transformer/look
sparking.
for shorts & repair.
Replace
electrodes/
transformer.
6.
No
air
pressure/defective
6. Turn compressor on/test
regulator/defective
solenoid. regulator/solenoid.
Replace defective
components.