LumaStream Trinity PERMANENT User Manual

Page 10

Advertising
background image

Document: 66APPMAN Rev: H

10 of 32

6.0

MOUNTING ORIENTATION

For sufficient cooling, the TRINITY LED Driver Dimmer must be mounted in
either a vertical or horizontal orientation as shown:

UP

Vertical orientation

provides the best

cooling option

Recommended mounting screw size #8 machine or self tapping screw

UP

UP

Document: 66APPMAN Rev: H

23 of 32

11.2 Output Zone/Channel Connections Table


Either 6, 9, or 12 output channel options are available for driving and
dimming LEDs. Channels are assigned to zones as shown in the following
tables. A 6 or 9 channel option will provide 3 zones for dimming and a 12
channel option will provide 4 zones for dimming.

Zone Number

Output Channel

Belden/Alpha or Equivalent Wire Color/

Polarity

1

1

WHT + / BLK -

1

2

RED

+ / BLK -

1

3

GREEN

+ / BLK -

2

4

WHT + / BLK -

2

5

RED

+ / BLK -

2

6

GREEN

+ / BLK -

3

7

WHT + / BLK -

3

8

RED

+ / BLK -

3

9

GREEN

+ / BLK -

4

10

WHT + / BLK -

4

11

RED

+ / BLK -

4

12

GREEN

+ / BLK -

Zone Number

Output Channel

Belden/Alpha or Equivalent Wire Color/

Polarity

1

1

WHT + /

GREEN

-

1

2

RED

+ / BLK -

2

3

WHT + /

GREEN

-

2

4

RED

+ / BLK -

3

5

WHT + /

GREEN

-

3

6

RED

+ / BLK -

9/12 Channel - Zone Connection Table