LumaStream Trinity PERMANENT User Manual

Page 6

Advertising
background image

Document: 66APPMAN Rev: H

6 of 32

Table 8

TRINITY Analog Model Options

Model #

# of

Channels

Drive

Current

Output Voltage

Range (under

load Conditions)

Maximum # of

LEDs per

Channel

(typical)

66-12-0600-ANA-3

12

600 mA

6 to 27 Vdc

2 to 8

66-12-0700-ANA-3

12

700 mA

6 to 27 Vdc

2 to 8

66-09-0800-ANA-3

9

800 mA

6 to 27 Vdc

2 to 8

66-09-0900-ANA-3

9

900 mA

6 to 27 Vdc

2 to 8

66-09-1000-ANA-3

9

1000 mA

6 to 27 Vdc

2 to 8

66-06-1200-ANA-3

6

1200 mA

6 to 27 Vdc

2 to 8

66-06-1400-ANA-3

6

1400 mA

6 to 27 Vdc

2 to 8

70-12-0300-ANA-3

12

300 mA

12 to 47 Vdc

4 to 12

70-12-0350-ANA-3

12

350 mA

12 to 47 Vdc

4 to 12

70-09-0400-ANA-3

9

400 mA

12 to 47 Vdc

4 to 12

70-09-0500-ANA-3

9

500mA

12 to 47 Vdc

4 to 12

70-06-0600-ANA-3

6

600 mA

12 to 47 Vdc

4 to 12

70-06-0700-ANA-3

6

700mA

12 to 47 Vdc

4 to 12

Table 9

Analog Interface Specifications

Control Method

Analog 0-10Vdc
IEC 60929 Annex E out-
puts 0.5mA maximum or
variable
0-10VDC voltage source;
class 2 outputs

Master, Zone1 Zone2, Zone3,
Zone4 outputs each source 0.5mA
maximum

Loss of Analog
Input Signal

Outputs will go to 100% light intensity in less than 1 second

Connection Method

UL recognized cage clamp connector
12 AWG to 28 AWG wiring

Electrical Isolation

Master, Zone 1, Zone 2, Zone 3, Zone 4 outputs
electrically isolated from earth ground

Document: 66APPMAN Rev: H

27 of 32

(1)TRINITY ANALOG, (1) COMMERCIAL DIMMING PANEL WITH
(4) 0-10VDC ANALOG CONTROL SIGNALS

Note: This wiring configuration provides independent dimming control
for each zone 1,2,3,4 with a commercial dimming interface comprising (4)
0-10Vdc control signals.

Advertising