Table 1

Input Specifications

Rated Input Voltage
And Frequency

115 to 277

47-63

Vac
Hz

Rated Input Current

A
A

66-xx-yyyy-zzz-n models

2.7-1.1

70-xx-yyyy-zzz-n models

2.4-1.0

Power Factor
EN61000-3-2

@ 115 Vac, 100% load

0.97

W/VA
min

Input Current Total
Harmonic Distortion

@ 115 Vac 100% load

13

% max

Table 2

Output Specifications

Rated Output
Power

66-xx-yyyy-xxx-n models
70-xx-yyyy-xxx-n models

@ 40 °C ambient


243
226

W max

Efficiency

100% load @
115 Vac input

87

%

Turn on delay

Time required for
stabilization of all

Outputs

2

sec

typical

Output Current
Tolerance

+/-5 % of nominal

Table 4

Environmental Specifications

Location Rating

Dry

Operating Ambient Temperature

-20ºC to +40ºC

Cold Start Temperature

-20ºC

Storage Ambient Temperature

-40ºC to 80ºC

Relative Humidity

5% to 95% noncondensing

MTBF (MIL HDBK-217F)
(12 channel)

>60,000 hours @ 40ºC
>97,000 hours @ 25ºC

Table 3

Safety and EMI/EMC Specifications

Agency Approvals

See Section 5.0

Conducted & Radiated Emissions

ICES-003
FCC Title 47, Part 15 Class A

EMC

EN61547-General Lighting

1.1 SPECIFICATIONS

Document: 66APPMAN Rev: H

29 of 32

12.0

0-10 Vdc MULTI-ZONE ANALOG INTERFACE


12.1 LED Status Indicator

Analog Dimming Indicator-Green LED will be in one of the following
states when the unit is powered:

Flashing Fast - Master Dimming input is at full On (100%)

Flashing Slow - Master Dimming input fully dimmed (0%)

Steady State - Green LED will vary in intensity proportionally to
master 0-10 Vdc control signal for intensity levels between 0%
and 100%.

Zone 10, 11, 12
Output

Zone 1,2,3
Output

Zone 7,8,9
Output

Zone 4,5,6
Output

Zone
Dimming Inter-
face Connections

Ana

log D

im

m

ing

Ind

ic

a

to

r

Master Dimming
Interface