Archive, Specifica, Specifica specifications tions tions tions tions – Ransburg 9040 Cascade LV Control Unit 76580 User Manual

Page 12

Advertising
background image

CP-97-04.3

9

9

9

9

9

9040 Cascade Low Voltage Control Unit - Introduction

SPECIFICA

SPECIFICA

SPECIFICA

SPECIFICA

SPECIFICATIONS

TIONS

TIONS

TIONS

TIONS

Environmental / Physical

Environmental / Physical

Environmental / Physical

Environmental / Physical

Environmental / Physical

Electrical Requirements

Electrical Requirements

Electrical Requirements

Electrical Requirements

Electrical Requirements

Input:

Input:

Input:

Input:

Input:
V

V

V

V

Voltage

oltage

oltage

oltage

oltage

90-264 VAC

Currentr:

Currentr:

Currentr:

Currentr:

Currentr:

0.4/0.2 Amps AC

Frequency:

Frequency:

Frequency:

Frequency:

Frequency:

50/60 Hertz

W

W

W

W

Wattage:

attage:

attage:

attage:

attage:

40 Watts (Maximum)

Output:

Output:

Output:

Output:

Output:
V

V

V

V

Voltage:

oltage:

oltage:

oltage:

oltage:

0-10 V RMS

Current:

Current:

Current:

Current:

Current:

1.5 Amp RMS (Maximum)

Pneumatic

Pneumatic

Pneumatic

Pneumatic

Pneumatic
Supply Air:

Supply Air:

Supply Air:

Supply Air:

Supply Air:

100 psi maximum

Height:

Height:

Height:

Height:

Height:

5.2-Inches

Width:

Width:

Width:

Width:

Width:

16.9-Inches
(19-Inches ear to ear)

Depth:

Depth:

Depth:

Depth:

Depth:

12.1-Inches

Weight:

Weight:

Weight:

Weight:

Weight:

15 lbs.

The 9040 Cascade control unit is available from
the factory in the following versions only:

1. One control unit with no Totalizer or Pneumatics
modules

2. One control unit with one Totalizer module and
no Pneumatics module

3. One control unit with one Totalizer module and
one Pneumatics module

4. One control unit with one Pneumatics module
and no Totalizer module

For applications requiring two Totalizer or
Pneumatics modules in a rack with one control
unit, the required modules can be purchased
separately as a kit. (See “Parts Identification”
section.)

The 13742-01 Air Flow Switch assembly used in
the following 9040 Control Units has a maximum
working pressure of 100 psi:

76580-1XXXX REA 70 Applicator
76580-6XXXX REA90 Waterborne Applicator
76580-7XXXX REA90 Solventborne Applicator

Exceeding this pressure may cause the flow
switch to burst. Ensure that the air input to the IN
port of the flow switch on these units is supplied
from a 100 psi or less regulated and filtered air
supply.

ARCHIVE

Advertising