Archive, 9040 cascade low vol – Ransburg 9040 Cascade LV Control Unit 76580 User Manual

Page 41

Advertising
background image

CP-97-04.3

3 8

3 8

3 8

3 8

3 8

9040 Cascade Low Voltage Control Unit - Parts Identification

(Continued On Next Page)

(Continued On Next Page)

(Continued On Next Page)

(Continued On Next Page)

(Continued On Next Page)

1

PC Board and Heat Sink Assembly:

76892-01

For 76580-1XXXX, REA70 Applicator (72074)

76892-02

For 76580-2XXXX, REM Applicator (72364)

76892-04

For 76580-4XXXX, REM Automatic (73499)

76892-05

For 76580-5XXXX, REA9000 Automatic (75795), Robot (76110), and
76580-BXXXX, REA900 Automatic (77359)

76892-06

For 76580-6XXXX, REA90 Waterborne Applicator (75786)

76892-07

For 76580-7XXXX, REA90 Solventborne Applicator (75785) and
76580-AXXXXX, M90 Applicator (77073)

76892-08

For 76580-8XXXX, REA90 Solventborne Automatic (75787X-XXXX1)

76892-09

For 76580-9XXXX, REA90 Waterborne Automatic (75787X-XXXX2)

76892-16

For 78398-01, Single Bell, Domestic

76892-17

For 78398-02, Single Bell, Export

2

76434-01

ON./OFF Switch

1SW

3

70556-03

High Voltage Adjust Potentiometer

1POT

4

76436-91

Kilovolt (kV) Meter

1M

5

76436-92

Microamp (uA)

2M

6

72231-00

Low Voltage Cable Socket

3SOC

7

13742-01

Air Flow Switch Assembly:

1FS

13028-01

Housing

8012-00

Switch Assembly

6039-00

Piston

25766-106

Pressure Switch *

1PS, 2PS

8

75337-05

Power Supply, 18VDC

1SUP

9

LSME082-04

Fuse, PC Board, Slow Blow, 4 Amp (See Figure 5 for location.)

F2

10

Fuse, Front Panel:

72771-06

Slow Blow, 1 Amp, 110-120 VAC Input

1FU

72771-01

Slow Blow, 0.5 Amp, 220-240 Input

1FU

11

76449-00

Detachable AC Line Cord

12

70539-00

Ground Wire Assembly

13

76455-01

LED Display Board

14

Overload Indicator and Reset Switch Assembly:

76442-01

Reset Switch (normally closed)

76441-00

Lens, Yellow

76443-01

Bulb

15

5627-00

Rubber Feet

16

Triple Setpoint/Analog Input Interface Board:

76031-05

For REA90 Solventborne Automatic

76031-06

For 76580-8XXXX, REA90 Waterborne Automatic

76031-07

Ror 76580-4XXXX, REM Automatic

76031-08

For REA9000 Automatic or Robot

76031-10

For 78398-01, Single Bell, Domestic

76892-11

For 78398-02, Single Bell, Export

76895-18

For 76580-BXXXX, REA900 Automatic

Item #

Item #

Item #

Item #

Item #

9040 CASCADE LOW VOL

9040 CASCADE LOW VOL

9040 CASCADE LOW VOL

9040 CASCADE LOW VOL

9040 CASCADE LOW VOLT

T

T

T

TAGE CONTROL

AGE CONTROL

AGE CONTROL

AGE CONTROL

AGE CONTROL UNIT

UNIT

UNIT

UNIT

UNIT - P

- P

- P

- P

- PAR

AR

AR

AR

ARTS LIST

TS LIST

TS LIST

TS LIST

TS LIST

(Figure 1

(Figure 1

(Figure 1

(Figure 1

(Figure 11)

1)

1)

1)

1)

Part #

Part #

Part #

Part #

Part #

Description

Description

Description

Description

Description

Notation

Notation

Notation

Notation

Notation

* Air flow switch used on 76580-1XXXX, -6XXXX, and -7XXXX.

Pressure switches used on 76580-4XXX, -5XXXX, -8XXXX, and -9XXXX.

ARCHIVE